12 ʻAno o ka maʻi hanu

Wehewehe Pōkole:

Hoʻohana ʻia kēia kit no ka hui ʻana o ka qualitative detection o SARS-CoV-2, influenza A virus, influenza B virus, adenovirus, mycoplasma pneumoniae, rhinovirus, respiratory syncytial virus a me parainfluenza virus (Ⅰ, II, III, IV) a me metapneumovirus kanaka i loko o nā swabs oropharyngeal..


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

HWTS-RT071A 12 ʻAno o ka Pahu ʻIke Waikawa Nucleic Pathogen Hanu (Fluorescence PCR)

Kanal

Kanal hu12Pākuʻi Hana A hu12Pahuhopu Hana B hu12Pahuhopu Hana C hu12ʻO ka Buffer Reaction D
ʻOhana SARS-CoV-2 HADV HPIV Ⅰ HRV
VIC/HEX Mana Kūloko Mana Kūloko HPIV II Mana Kūloko
CY5 IFV A MP HPIV III /
ROX IFV B RSV HPIV Ⅳ HMPV

Nā Palena ʻenehana

Ka Waihona

≤-18℃

Ola papa 12 mahina
ʻAno Laʻana ʻUwila waha
Ct ≤38
CV ≤5.0%
LoD SARS-CoV-2:300 Kope/mLmaʻi influenza B:500 Kope/mLmaʻi influenza A:500 Kope/mL

Adenovirus:500 Kope/mL

mycoplasma pneumoniae:500 Kope/mL

ka maʻi syncytial hanu:500 Kope/mL,

ʻO ka maʻi parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 Kope/mL

Rhinovirus:500 Kope/mL

ka metapneumovirus kanaka:500 Kope/mL

Kūlana kikoʻī Ua hōʻike ʻia ka haʻawina cross-reactivity ʻaʻohe cross-reactivity ma waena o kēia kit a me ka enterovirus A, B, C, D, epstein-barr virus, measles virus, human cytomegalovirus, rotavirus, norovirus, mumps virus, varicella-herpes zoster virus, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans a me ka human genomic nucleic acid.
Nā Mea Hana Pili Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa MaoliNā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 ʻōnaehana PCR Manawa Maoli,

ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus(FQD-96A,ʻenehana Hangzhou Bioer)

MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.)

ʻŌnaehana PCR Manawa Maoli BioRad CFX96

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kahe Hana

Koho 1.

ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Pono e hoʻokō ʻia ka unuhi ʻana e like me nā kuhikuhi.

 Koho 2.

ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) a me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., pono e hana ʻia ka hoʻoheheʻe e like me nā kuhikuhi me ka pololei. ʻO ka nui o ka elution i ʻōlelo ʻia he 80μL.

 Koho 3.

ʻO ka mea hoʻohuihui i ʻōlelo ʻia: Nucleic Acid Extraction or Purification Kit (YDP315) na Tiangen Biotech (Beijing) Co., Ltd., pono e hana ʻia ka unuhi ʻana e like me nā kuhikuhi me ka pololei. ʻO ka nui o ka elution i ʻōlelo ʻia he 100μL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou