12 ʻAno o ka maʻi hanu
Inoa huahana
HWTS-RT071A 12 ʻAno o ka Pahu ʻIke Waikawa Nucleic Pathogen Hanu (Fluorescence PCR)
Kanal
| Kanal | hu12Pākuʻi Hana A | hu12Pahuhopu Hana B | hu12Pahuhopu Hana C | hu12ʻO ka Buffer Reaction D |
| ʻOhana | SARS-CoV-2 | HADV | HPIV Ⅰ | HRV |
| VIC/HEX | Mana Kūloko | Mana Kūloko | HPIV II | Mana Kūloko |
| CY5 | IFV A | MP | HPIV III | / |
| ROX | IFV B | RSV | HPIV Ⅳ | HMPV |
Nā Palena ʻenehana
| Ka Waihona | ≤-18℃ |
| Ola papa | 12 mahina |
| ʻAno Laʻana | ʻUwila waha |
| Ct | ≤38 |
| CV | ≤5.0% |
| LoD | SARS-CoV-2:300 Kope/mLmaʻi influenza B:500 Kope/mLmaʻi influenza A:500 Kope/mL Adenovirus:500 Kope/mL mycoplasma pneumoniae:500 Kope/mL ka maʻi syncytial hanu:500 Kope/mL, ʻO ka maʻi parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 Kope/mL Rhinovirus:500 Kope/mL ka metapneumovirus kanaka:500 Kope/mL |
| Kūlana kikoʻī | Ua hōʻike ʻia ka haʻawina cross-reactivity ʻaʻohe cross-reactivity ma waena o kēia kit a me ka enterovirus A, B, C, D, epstein-barr virus, measles virus, human cytomegalovirus, rotavirus, norovirus, mumps virus, varicella-herpes zoster virus, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans a me ka human genomic nucleic acid. |
| Nā Mea Hana Pili | Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa MaoliNā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.) LightCycler®480 ʻōnaehana PCR Manawa Maoli, ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus(FQD-96A,ʻenehana Hangzhou Bioer) MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.) ʻŌnaehana PCR Manawa Maoli BioRad CFX96 ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96 |
Kahe Hana
Koho 1.
ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Pono e hoʻokō ʻia ka unuhi ʻana e like me nā kuhikuhi.
Koho 2.
ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) a me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., pono e hana ʻia ka hoʻoheheʻe e like me nā kuhikuhi me ka pololei. ʻO ka nui o ka elution i ʻōlelo ʻia he 80μL.
Koho 3.
ʻO ka mea hoʻohuihui i ʻōlelo ʻia: Nucleic Acid Extraction or Purification Kit (YDP315) na Tiangen Biotech (Beijing) Co., Ltd., pono e hana ʻia ka unuhi ʻana e like me nā kuhikuhi me ka pololei. ʻO ka nui o ka elution i ʻōlelo ʻia he 100μL.