28 ʻAno o ka Human Papilloma Virus kiʻekiʻe (16/18 Typing) Nucleic Acid

Wehewehe Pōkole:

He kūpono kēia pahu no ka ʻike ʻana i ka qualitative in vitro o 28 mau ʻano o nā maʻi papilloma kanaka (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) nucleic acid i loko o ka mimi kāne/wahine a me nā pūnaewele exfoliated cervical wahine. Hiki ke ʻano ʻia ka HPV 16/18, ʻaʻole hiki ke ʻano ʻia nā ʻano i koe, e hāʻawi ana i kahi ala kōkua no ka ʻike ʻana a me ka mālama ʻana i ka maʻi HPV.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

HWTS-CC006A-28 Nā ʻAno o ka Human Papilloma Virus Kiʻekiʻe (16/18 Typing) Pahu ʻIke Waikawa Nucleic (Fluorescence PCR)

ʻAlapia

ʻO ke kanesa ʻōpū kekahi o nā puʻupuʻu ʻino maʻamau o ka ʻōnaehana hānau wahine. Ua hōʻike ʻia nā haʻawina ʻo nā maʻi mau o ka HPV a me nā maʻi he nui kekahi o nā kumu nui o ke kanesa ʻōpū. I kēia manawa, ʻaʻohe mau lāʻau lapaʻau kūpono i ʻike ʻia no ke kanesa ʻōpū i hoʻokumu ʻia e ka HPV, no laila ʻo ka ʻike mua ʻana a me ka pale ʻana i ka maʻi ʻōpū i hoʻokumu ʻia e ka HPV ke kī i ka pale ʻana i ke kanesa ʻōpū. He mea nui loa ka hoʻokumu ʻana i kahi hoʻāʻo diagnostic etiology maʻalahi, kikoʻī a wikiwiki hoʻi no ka ʻike lapaʻau a me ka mālama ʻana i ke kanesa ʻōpū.

Kanal

Hoʻohuihui Hana Kanal ʻAno
PCR-Mix1 ʻOhana 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Mana Kūloko
PCR-Mix2 ʻOhana 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Mana Kūloko

Nā Palena ʻenehana

Ka Waihona Wai: ≤-18 ℃
Ola papa 12 mahina
ʻAno Laʻana ʻUpena Cervical, ʻUpena Vaginal, Mimi
Ct ≤28
CV <5.0%
LoD 300 Kope/mL
Nā Mea Hana Pili Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli
Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500
QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli
Nā ʻōnaehana PCR Manawa Maoli SLAN-96P
LightCycler®ʻŌnaehana PCR Manawa Maoli 480
ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus
MA-6000 Mea Hoʻopololei Wela Manawa Maoli
ʻŌnaehana PCR Manawa Maoli BioRad CFX96
ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kahe Hana

Mea hoʻohuihui i manaʻo ʻia: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. E hoʻohui i 200μL o ka saline maʻamau e hoʻokuʻu hou i ka pellet ma ka hana 2.1, a laila e hana ʻia ka unuhi ʻana e like me nā kuhikuhi no ka hoʻohana ʻana i kēia mea hoʻohuihui. ʻO ka nui o ka elution i manaʻo ʻia he 80μL.
ʻO ka mea hoʻohuihui i ʻōlelo ʻia: QIAamp DNA Mini Kit (51304) a i ʻole Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). E hoʻohui i 200μL o ka saline maʻamau e hoʻokuʻu hou i ka pellet ma ka hana 2.1, a laila pono e hana ʻia ka unuhi ʻana e like me nā kuhikuhi no ka hoʻohana ʻana i kēia mea hoʻohuihui. ʻO ka nui o ka laʻana i unuhi ʻia o nā laʻana he 200μL a pau, a ʻo ka nui o ka elution i ʻōlelo ʻia he 100μL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou