28 Nā ʻano o ka maʻi maʻi papilloma kanaka kiʻekiʻe (16/18 paʻi) ʻakika nucleic

ʻO ka wehewehe pōkole:

He kūpono kēia pahu no ka ʻike in vitro qualitative o 28 mau ʻano o nā maʻi papilloma kanaka (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 55, 53, 52, 53 61, 66, 68, 73, 81, 82, 83) ʻakika nucleic i loko o ka mimi kāne/wahine a me nā pūnaeho exfoliated cervical wahine. Hiki ke paʻi ʻia ka HPV 16/18, ʻaʻole hiki ke paʻi piha ʻia nā ʻano i koe, e hāʻawi ana i mea kōkua no ka ʻike a me ka mālama ʻana i ka maʻi HPV.


Huahana Huahana

Huahana Huahana

inoa huahana

HWTS-CC006A-28 Nā ʻano o ka maʻi maʻi papilloma kanaka kiʻekiʻe (16/18 paʻi ʻana) pahu ʻike ʻakika nucleic (Fluorescence PCR)

Epidemiology

ʻO ka maʻi ʻaʻai ʻāʻī kekahi o nā maʻi maʻi maʻamau o ka ʻāpana hānau wahine. Ua hōʻike ʻia nā haʻawina ʻo nā maʻi hoʻomau HPV a me nā maʻi he nui kekahi o nā kumu nui o ka maʻi kanesa cervical. I kēia manawa, ʻaʻole i ʻike ʻia nā lāʻau lapaʻau maikaʻi no ka maʻi maʻi ʻāʻī ma muli o ka HPV, no laila, ʻo ka ʻike mua ʻana a me ka pale ʻana i ka maʻi ʻāʻī i hoʻokumu ʻia e ka HPV ʻo ia ke kī i ka pale ʻana i ka maʻi maʻi cervical. He mea koʻikoʻi ka hoʻokumu ʻana i kahi hōʻike diagnostic etiology maʻalahi, kikoʻī a wikiwiki hoʻi no ka maʻi maʻi a me ka mālama ʻana i ka maʻi maʻi cervical.

Kanal

Hui Hana Kanal ʻAno
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Hoomalu Kuloko
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Hoomalu Kuloko

Nā ʻāpana ʻenehana

Waihona Ka wai: ≤-18 ℃
Kau-ola 12 mahina
ʻAno Hoʻohālike ʻO ka ʻauʻau ʻāʻī, ka ʻāwīwīwī, ka mimi
Ct ≤28
CV <5.0%
LoD 300 kope/mL
Nā mea hana pili Hoʻohana ʻia Biosystems 7500 Pūnaehana PCR manawa maoli
Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems
QuantStudio®5 Pūnaehana PCR manawa maoli
SLAN-96P Pūnaehana PCR Manawa maoli
LightCycler®480 Pūnaehana PCR manawa maoli
LineGene 9600 Plus Pūnaehana ʻike PCR manawa maoli
MA-6000 Mea Hoʻokele Thermal Cycler manawa maoli
BioRad CFX96 Pūnaehana PCR Manawa maoli
BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli

Holo Hana

Manaʻo ʻia ka hoʻoneʻe ʻana: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (000HWC Acid Extractor). HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hana ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent extraction. ʻO ka nui o ka elution i manaʻo ʻia he 80μL.
Manaʻo ʻia ka mea hoʻoheheʻe: QIAamp DNA Mini Kit (51304) a i ʻole Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). E hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hoʻokō ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent. He 200μL ka nui o nā laʻana i unuhi ʻia, a ʻo ka nui elution i ʻōlelo ʻia he 100μL.


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou