ʻO Chlamydia Trachomatis, Neisseria Gonorrhoeae a me Trichomonas vaginalis

ʻO ka wehewehe pōkole:

Kuhi ʻia ka pahu no ka ʻike in vitro qualitative o Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG)aʻO Trichomonal vaginitis (TV) i loko o ke kane urethral swab, wahine cervical swab, a me ka wahine vaginal swab samples, a hāʻawi i ke kōkua i ka ʻike a me ka mālama ʻana i nā maʻi me nā maʻi maʻi genitourinary.


Huahana Huahana

Huahana Huahana

Inoa mea kūʻai

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae a me Trichomonas vaginalis Mea ʻImi ʻAka Nucleic (Fluorescence PCR)

Epidemiology

ʻO Chlamydia trachomatis (CT) kahi ʻano microorganism prokaryotic i paʻa paʻa i loko o nā cell eukaryotic.Hoʻokaʻawale ʻia ʻo Chlamydia trachomatis i AK serotypes e like me ke ʻano serotype.ʻO nā maʻi maʻi urogenital ka hapa nui o ka trachoma biological variant DK serotypes, a ʻike ʻia nā kāne ma ke ʻano he urethritis, hiki ke hoʻomaha ʻia me ka ʻole o ka mālama ʻana, akā ʻo ka hapa nui o lākou e lilo i ka maʻi maʻi, hoʻonui pinepine ʻia, a hiki ke hui pū ʻia me ka epididymitis, proctitis, etc.

Kanal

FAM ʻO Chlamydia trachomatis
ROX Neisseria gonorrhoeae
CY5 Trichomonal vaginitis
VIC/HEX Hoomalu Kuloko

Nā ʻāpana ʻenehana

Waihona

-18 ℃

Kau-ola 12 mahina
ʻAno Hoʻohālike ʻO ka pulupulu wahine,Wahine vaginal swabʻAhu ʻāʻī kāne
Ct ≤38
CV <5%
LoD 400Nā kope/mL
kikoo ʻAʻohe ʻano hoʻololi ʻē aʻe me nā pathogens maʻi STD ʻē aʻe ma waho o ka pae ʻike o ka pahu hoʻāʻo, e like me Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, etc.
Nā mea hana pili Hoʻohana ʻia ʻo Biosystems 7500 Pūnaehana PCR manawa maoli

Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Pūnaehana PCR manawa maoli

SLAN-96P Pūnaehana PCR Manawa maoli

LightCycler®480 Pūnaehana PCR manawa maoli

LineGene 9600 Plus Pūnaehana ʻike PCR manawa maoli

MA-6000 ʻOiaʻiʻo ka nui o ka wela wela

BioRad CFX96 Pūnaehana PCR Manawa maoli

BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli

Holo Hana

Koho 1.

Manaʻo ʻia ka mea hoʻihoʻi: Pipette 1mL o ka hāpana e hoʻāʻo ʻia i kahi 1.5mL o DNase/RNase-free centrifuge tube, centrifuge ma 12000rpm no 3 mau minuke, e hoʻolei i ka supernatant a mālama i ka precipitate.E hoʻohui i 200µL o ka paʻakai maʻamau i ka precipitate e hoʻomaha hou.Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e hana ʻia ka unuhi e like me ke kuhikuhi no ka hoʻohana ʻana.ʻO 200µL ka nui o ka laʻana, a ʻo ka nui o ka elution i manaʻo ʻia he 80µL.

Koho 2.

Manaʻo ʻia ka mea hoʻoneʻe hoʻoneʻe: Nucleic Acid Extraction a i ʻole Cleaning Kit (YDP302).Pono e hoʻokō pono ʻia ka unuhi ʻana e like me ke kuhikuhi no ka hoʻohana ʻana.ʻO ka nui o ka elution i manaʻo ʻia he 80µL.


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou