Ka maʻi Hepatitis A

Wehewehe Pōkole:

He kūpono kēia pahu hana no ka ʻike ʻana i ka waikawa nucleic o ka maʻi hepatitis A (HAV) i loko o nā laʻana serum a me nā laʻana ʻōpala in vitro.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

Pahu ʻIke Waikawa Nukleika no ka Maʻi Hepatitis A HWTS-HP005 (Fluorescence PCR)

ʻAlapia

ʻO ka maʻi Hepatitis A (HAV) ke kumu nui o ka maʻi hepatitis viral koʻikoʻi. He maʻi RNA kaula hoʻokahi maikaʻi ka maʻi a no ka ʻano Hepadnavirus o ka ʻohana Picornaviridae. ʻO ka maʻi Hepatitis A, i hoʻolaha nui ʻia ma ke ala fecal-oral, kūpaʻa i ka wela, nā waikawa, a me ka hapa nui o nā mea hoʻoheheʻe organik, hiki ke ola no ka manawa lōʻihi i loko o nā iʻa paʻi, ka wai, ka lepo, a i ʻole nā ​​​​​​mea hoʻoheheʻe kai [1-3]. Hoʻolaha ʻia ma ka loaʻa ʻana o ka meaʻai a i ʻole ka wai i haumia, a i ʻole i hoʻolaha pololei ʻia mai ke kanaka a i ke kanaka. ʻO nā meaʻai e pili ana me HAV e komo pū me nā oysters a me nā clams, nā strawberries, nā raspberries, nā blueberries, nā lā, nā lau ʻai ʻōmaʻomaʻo, a me nā tōmato maloʻo hapa [4‒6].

Kanal

ʻOhana ʻAkika nukleika HAV
ROX

Mana Kūloko

Nā Palena ʻenehana

Ka Waihona

≤-18℃

Ola papa Wai: 9 mahina, Lyophilized: 12 mahina
ʻAno Laʻana Serum/noho
Tt ≤38
CV ≤5.0%
LoD 2 Kope/μL
Kūlana kikoʻī E hoʻohana i nā kime e hoʻāʻo i nā maʻi hepatitis ʻē aʻe e like me ka hepatitis B, C, D, E, enterovirus 71, coxsackie virus, Epstein-Barr virus, norovirus, HIV a me ka genome kanaka. ʻAʻohe cross-reactivity.
Nā Mea Hana Pili ʻŌnaehana PCR Manawa Maoli Biosystems 7500 i hoʻopili ʻia

Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500

QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.)

ʻŌnaehana PCR Manawa Maoli LightCycler®480

ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler

ʻŌnaehana PCR Manawa Maoli BioRad CFX96

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kahe Hana

Nā hāpana serum

Koho 1.

ʻO ka Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) a me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). Pono e unuhi ʻia e like me nā kuhikuhi. ʻO ka nui o ka elution i ʻōlelo ʻia he 80µL.

Koho 2.

ʻO ka TIANamp Virus DNA/RNA Kit (YDP315-R) i hana ʻia e Tiangen Biotech (Beijing) Co., Ltd. Pono e unuhi ʻia e like me nā kuhikuhi. ʻO ka nui o ka laʻana i unuhi ʻia he 140μL. ʻO ka nui o ka elution i ʻōlelo ʻia he 60µL.

2.Nā Laʻana Noho

ʻO ka Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) a me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). Pono e unuhi ʻia e like me nā kuhikuhi. ʻO ka nui o ka elution i ʻōlelo ʻia he 80µL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā māhele huahana