Human Papillomavirus (28 ʻAno) Genotyping

ʻO ka wehewehe pōkole:

Hoʻohana ʻia kēia pahu no ka ʻike qualitative a me ka genotyping o ka waikawa nucleic o 28 mau ʻano o ka papillomavirus kanaka (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 55, 5, 5, 5, 5, 5, 5 61, 66, 68, 73, 81, 82, 83) i loko o ka mimi kāne/kane a me ka wahine cervical exfoliated cell, e hāʻawi ana i nā mea kōkua no ka hōʻoia a me ka mālama ʻana i ka maʻi HPV.


Huahana Huahana

Huahana Huahana

inoa huahana

HWTS-CC013-Human Papillomavirus (28 Nā ʻano) Genotyping Detection Kit (Fluorescence PCR)

HWTS-CC016A-Hoʻomaloʻo i ka Human Papillomavirus (28 mau ʻano) pahu ʻike Genotyping (Fluorescence PCR)

Epidemiology

ʻO ka maʻi ʻaʻai ʻāʻī kekahi o nā maʻi maʻi maʻamau o ka ʻāpana hānau wahine. Ua hōʻike ʻia nā haʻawina mua ʻo ka maʻi hoʻomau a me nā maʻi lehulehu o ka papillomavirus kanaka kekahi o nā kumu nui o ka maʻi maʻi cervical. I kēia manawa, aia nō ka nele o nā lāʻau lapaʻau kūpono no ka HPV, no laila ʻo ka ʻike mua ʻana a me ka pale ʻana i ka HPV cervical nā kī e pale ai i ka maʻi kanesa. No ka hoʻokumu ʻana i kahi ala maʻalahi, kikoʻī a wikiwiki hoʻi i ka etiological diagnostic method he mea koʻikoʻi nui i ka maʻi maʻi o ka maʻi maʻi cervical.

Kanal

Hoʻopaʻa pānaʻi FAM VIC/HEX ROX CY5
HPV Genotyping Reaction Buffer 1 16 18 / Ka hooponopono kuloko
HPV Genotyping Reaction Buffer 2 56 / 31 Ka hooponopono kuloko
HPV Genotyping Reaction Buffer 3 58 33 66 35
HPV Genotyping Reaction Buffer 4 53 51 52 45
HPV Genotyping Reaction Buffer 5 73 59 39 68
HPV Genotyping Reaction Buffer 6 6 11 83 54
HPV Genotyping Reaction Buffer 7 26 44 61 81
HPV Genotyping Reaction Buffer 8 40 43 42 82

Nā ʻāpana ʻenehana

Waihona Ka wai: ≤-18 ℃
Kau-ola 12 mahina
ʻAno Hoʻohālike ʻO ka ʻauʻau ʻāʻī, ka ʻāwīwīwī, ka mimi
Ct ≤28
CV ≤5.0%
LoD 300 kope/mL
kikoʻī ʻAʻole maikaʻi nā hopena a pau ke hoʻohana ʻia ka kit e ʻike i nā ʻano kikoʻī ʻole i loaʻa nā ʻano like ʻole me ia, me ka ureaplasma urealyticum, chlamydia trachomatis o ka ʻaoʻao hānau, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella a me nā ʻano kiʻi HPV ʻaʻole i uhi ʻia e ka HPV.
Nā mea hana pili Hoʻohana ʻia ʻo Biosystems 7500 Pūnaehana PCR manawa maoli

Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Pūnaehana PCR manawa maoli

SLAN-96P Pūnaehana PCR Manawa maoli

LightCycler®480 Pūnaehana PCR Manawa maoli

LineGene 9600 Plus Pūnaehana ʻIke PCR manawa maoli

MA-6000 ʻOiaʻiʻo ka nui o ka wela wela

BioRad CFX96 Pūnaehana PCR Manawa maoli

BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli

Holo Hana

Koho 1.

Manaʻo ʻia nā mea hoʻihoʻi hou: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8)

Koho 2.

Manaʻo ʻia nā reagents unuhi: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) a me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou