17 Nā ʻano o ka HPV (16/18/6/11/44 Ke kikokiko ʻana)

ʻO ka wehewehe pōkole:

He kūpono kēia pahu no ka ʻike qualitative o 17 mau ʻano papillomavirus (HPV) ʻano (HPV 6, 11, 16,18,31, 33,35, 39, 44,45, 51, 52.56,58, 59,66, 68) nā ʻāpana ʻakika nucleic kikoʻī i loko o ka laʻana mimi, ka laʻana o ka puʻu ʻana o ka ʻōpū o ka wahine a me ka laʻana o ka swab vaginal wahine, a me ka HPV 16/18/6/11/44 e paʻi ana e kōkua i ka ʻike a mālama ʻana i ka maʻi HPV.


Huahana Huahana

Huahana Huahana

Inoa mea kūʻai

HWTS-CC015 17 Nā ʻano o ka Human Papillomavirus (16/18/6/11/44 Type) Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

ʻO ka maʻi ʻaʻai ʻāʻī kekahi o nā maʻi maʻi maʻamau i ka ʻāpana hānau wahine.Ua hōʻike ʻia ʻo ka maʻi HPV mau a me nā maʻi he nui kekahi o nā kumu nui o ka maʻi maʻi ʻāʻī.I kēia manawa aia ka nele o nā lāʻau lapaʻau maikaʻi i ʻae ʻia no ka maʻi maʻi ʻāʻī ma muli o ka HPV.No laila, ʻo ka ʻike mua ʻana a me ka pale ʻana i ka maʻi ʻāʻī o ka maʻi i hoʻokumu ʻia e ka HPV ʻo ia ke kī i ka pale ʻana i ka maʻi kanesa cervical.ʻO ka hoʻokumu ʻana i nā hoʻokolohua maʻalahi, kikoʻī a wikiwiki hoʻi no nā pathogens he mea koʻikoʻi nui ia no ka hōʻoia ʻana i ka maʻi maʻi cervical.

Kanal

PCR-Mix1 FAM 18
VIC/HEX

16

ROX

31,33,35,39,45,51,52,56,58,59,66,68

CY5 Ka hooponopono kuloko
PCR-Mix2 FAM 6
VIC/HEX

11

ROX

44

CY5 Ka hooponopono kuloko

Nā ʻāpana ʻenehana

Waihona

-18 ℃

Kau-ola 12 mahina
ʻAno Hoʻohālike Laʻana mimi, laʻana ʻaʻahu ʻāʻī o ka ʻōpū o ka wahine, kahi laʻana swab wahine
Ct ≤28
LoD 300 kope/mL
kikoo ʻAʻohe hoʻololi keʻa me Ureaplasma urealyticum, Chlamydia trachomatis o ka ʻāpana hānau, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mold, Gardnerella a me nā ʻano HPV ʻē aʻe i uhi ʻole ʻia e ka pahu.
Nā mea hana pili Hoʻohana ʻia Biosystems 7500 Pūnaehana PCR manawa maoli
Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems
QuantStudio®5 Pūnaehana PCR manawa maoli
SLAN-96P Pūnaehana PCR Manawa maoli
LightCycler®480 Pūnaehana PCR Manawa maoli
LineGene 9600 Plus Pūnaehana ʻIke PCR manawa maoli
MA-6000 ʻOiaʻiʻo ka nui o ka wela wela
BioRad CFX96 Pūnaehana PCR Manawa maoli
BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli

Holo Hana

Manaʻo ʻia ka hoʻoulu ʻana: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test ʻO ka Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. E hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hana ʻia ka unuhi e like me i nā ʻōlelo kuhikuhi no ka hoʻohana ʻana i kēia reagent.ʻO ka nui o ka elution i manaʻo ʻia he 80μL.

Manaʻo ʻia ka mea hoʻihoʻi hou: QIAamp DNA Mini Kit (51304) a i ʻole Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).E hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hoʻokō ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent.He 200μL ka nui o nā laʻana i unuhi ʻia, a ʻo ka nui elution i ʻōlelo ʻia he 100μL.

Manaʻo ʻia ka mea hoʻoheheʻe: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L).E hoʻohui i 200μL o ka laʻana hoʻokuʻu reagent e hoʻokuʻu hou i ka pellet ma ka ʻanuʻu 2.1, a laila pono e hana ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent.