Epidemiology
ʻO ka maʻi ʻaʻai ʻāʻī kekahi o nā maʻi maʻi maʻamau i ka ʻāpana hānau wahine.Ua hōʻike ʻia ʻo ka maʻi HPV mau a me nā maʻi he nui kekahi o nā kumu nui o ka maʻi maʻi ʻāʻī.I kēia manawa aia ka nele o nā lāʻau lapaʻau maikaʻi i ʻae ʻia no ka maʻi maʻi ʻāʻī ma muli o ka HPV.No laila, ʻo ka ʻike mua ʻana a me ka pale ʻana i ka maʻi ʻāʻī o ka maʻi i hoʻokumu ʻia e ka HPV ʻo ia ke kī i ka pale ʻana i ka maʻi kanesa cervical.ʻO ka hoʻokumu ʻana i nā hoʻokolohua maʻalahi, kikoʻī a wikiwiki hoʻi no nā pathogens he mea koʻikoʻi nui ia no ka hōʻoia ʻana i ka maʻi maʻi cervical.
Kanal
PCR-Mix1 | FAM | 18 |
VIC/HEX | 16 | |
ROX | 31,33,35,39,45,51,52,56,58,59,66,68 | |
CY5 | Ka hooponopono kuloko |
PCR-Mix2 | FAM | 6 |
VIC/HEX | 11 | |
ROX | 44 | |
CY5 | Ka hooponopono kuloko |
Nā ʻāpana ʻenehana
Waihona | -18 ℃ |
Kau-ola | 12 mahina |
ʻAno Hoʻohālike | Laʻana mimi, laʻana ʻaʻahu ʻāʻī o ka ʻōpū o ka wahine, kahi laʻana swab wahine |
Ct | ≤28 |
LoD | 300 kope/mL |
kikoo | ʻAʻohe hoʻololi keʻa me Ureaplasma urealyticum, Chlamydia trachomatis o ka ʻāpana hānau, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mold, Gardnerella a me nā ʻano HPV ʻē aʻe i uhi ʻole ʻia e ka pahu. |
Nā mea hana pili | Hoʻohana ʻia Biosystems 7500 Pūnaehana PCR manawa maoli Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Pūnaehana PCR manawa maoli SLAN-96P Pūnaehana PCR Manawa maoli LightCycler®480 Pūnaehana PCR Manawa maoli LineGene 9600 Plus Pūnaehana ʻIke PCR manawa maoli MA-6000 ʻOiaʻiʻo ka nui o ka wela wela BioRad CFX96 Pūnaehana PCR Manawa maoli BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli |
Holo Hana
Manaʻo ʻia ka hoʻoulu ʻana: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test ʻO ka Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. E hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hana ʻia ka unuhi e like me i nā ʻōlelo kuhikuhi no ka hoʻohana ʻana i kēia reagent.ʻO ka nui o ka elution i manaʻo ʻia he 80μL.
Manaʻo ʻia ka mea hoʻihoʻi hou: QIAamp DNA Mini Kit (51304) a i ʻole Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).E hoʻohui i 200μL o ka paʻakai maʻamau e hoʻokuʻu hou i ka pellet ma ka pae 2.1, a laila pono e hoʻokō ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent.He 200μL ka nui o nā laʻana i unuhi ʻia, a ʻo ka nui elution i ʻōlelo ʻia he 100μL.
Manaʻo ʻia ka mea hoʻoheheʻe: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L).E hoʻohui i 200μL o ka laʻana hoʻokuʻu reagent e hoʻokuʻu hou i ka pellet ma ka ʻanuʻu 2.1, a laila pono e hana ʻia ka unuhi e like me nā kuhikuhi no ka hoʻohana ʻana i kēia reagent.