28 ʻAno o ka HPV Nucleic Acid Detection Kit (Fluorescence PCR)
Inoa huahana
28 ʻAno o ka HPV Nucleic Acid Detection Kit (Fluorescence PCR)
ʻAlapia
No ka ʻohana Papillomaviridae ka Human Papillomavirus (HPV) o kahi maʻi DNA poepoe pālua liʻiliʻi, ʻaʻole i hoʻopuni ʻia, me ka lōʻihi o ka genome ma kahi o 8000 mau hui kumu (bp). Hoʻopilikia ka HPV i nā kānaka ma o ka pili pololei a ʻaʻole paha me nā mea i haumia a i ʻole ka lawe ʻana i ka moekolohe. ʻAʻole wale ka maʻi i kikoʻī i ka mea hoʻokipa, akā i kikoʻī pū kekahi, a hiki ke hoʻopilikia wale i ka ʻili kanaka a me nā pūnaewele epithelial mucosal, e hana ana i nā ʻano papillomas a i ʻole nā warts i loko o ka ʻili kanaka a me ka hōʻino nui ʻana i ka epithelium o ke ala hānau.
ʻO ke kanesa ʻōpū kekahi o nā puʻupuʻu ʻino maʻamau o ka ʻōnaehana hānau wahine. Ua hōʻike ʻia nā haʻawina ʻo nā maʻi mau o ka HPV a me nā maʻi he nui kekahi o nā kumu nui o ke kanesa ʻōpū. I kēia manawa, ʻaʻohe mau lāʻau lapaʻau kūpono i ʻike ʻia no ke kanesa ʻōpū i hoʻokumu ʻia e ka HPV, no laila ʻo ka ʻike mua ʻana a me ka pale ʻana i ka maʻi ʻōpū i hoʻokumu ʻia e ka HPV ke kī i ka pale ʻana i ke kanesa ʻōpū. He mea nui loa ka hoʻokumu ʻana i kahi hoʻāʻo diagnostic etiology maʻalahi, kikoʻī a wikiwiki hoʻi no ka ʻike lapaʻau a me ka mālama ʻana i ke kanesa ʻōpū.
Kanal
| S/N | Kanal | ʻAno |
| PCR-Mix1 | ʻOhana | 16, 18, 31, 56 |
| VIC(HEX) | Mana Kūloko | |
| CY5 | 45, 51, 52, 53 | |
| ROX | 33, 35, 58, 66 | |
| PCR-Mix2 | ʻOhana | 6, 11, 54, 83 |
| VIC(HEX) | 26, 44, 61, 81 | |
| CY5 | 40, 42, 43, 82 | |
| ROX | 39, 59, 68, 73 |
Nā Palena ʻenehana
| Ka Waihona | ≤ -18℃ |
| Ola papa | 12 mahina |
| ʻAno Laʻana | Hāʻina mimi, Hāʻina swab cervical wahine, Hāʻina swab vaginal wahine |
| CV | <5.0% |
| LoD | 300 Kope/mL |
| Kūlana kikoʻī | ʻAʻohe hopena keʻa me nā pathogens ʻē aʻe e pili ana i ke ʻano hānau a me ka DNA genomic kanaka. |
| Nā Mea Hana Pili | ʻŌnaehana PCR Manawa Maoli Biosystems 7500 i hoʻopili ʻia, ʻŌnaehana PCR Manawa Maoli Wikiwiki Biosystems 7500 i hoʻopili ʻia, ʻŌnaehana PCR Manawa Maoli QuantStudio®5, ʻŌnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.), ʻŌnaehana PCR Manawa Maoli LightCycler®480, ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer), MA-6000 Cycler Thermal Quantitative Manawa Maoli (Suzhou Molarray Co., Ltd.), ʻŌnaehana PCR Manawa Maoli BioRad CFX96, ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96. |
Kaʻina hana: E nānā i ka Kit IFU no nā kikoʻī
Hoʻonā 1 (Hoʻopuka ʻakomi ʻia ka waikawa nucleic)
Hoʻonā 2: (Macro & Micro-Test Laʻana Hoʻokuʻu Reagent)
Pono nā reagents akā ʻaʻole i hāʻawi ʻia
ʻO ka Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).
Pono nā mea hoʻopau akā ʻaʻole i hāʻawi ʻia
1.5mL o nā paipu ʻole DNase/RNase, nā wēlau ʻole DNase/RNase, nā ʻāpana paipu 8 no PCR, centrifuge papaʻaina, mea hoʻohuihui lūlū papaʻaina.