ʻO Adenovirus Universal

Wehewehe Pōkole:

Hoʻohana ʻia kēia pahu hana no ka ʻike qualitative o ka adenovirus nucleic acid i loko o ka nasopharyngeal swab a me ka ʻāʻī swab laʻana.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

Pahu ʻIke Waikawa Nukleika Honua HWTS-RT017A Adenovirus (Fluorescence PCR)

ʻAlapia

No ka genus Mammalian adenovirus ka adenovirus kanaka (HAdV), he virus DNA kaula pālua me ka ʻole o ka envelope. ʻO nā adenovirus i loaʻa a hiki i kēia manawa he 7 mau subgroups (AG) a me 67 mau ʻano, nona he 55 serotypes he pathogenic i nā kānaka. I waena o lākou, ʻo ka mea hiki ke alakaʻi i nā maʻi ʻōpū hanu ʻo ia ka hui B (ʻAno 3, 7, 11, 14, 16, 21, 50, 55), Hui C (ʻAno 1, 2, 5, 6, 57) a me Hui E (ʻAno 4), a ʻo ka mea hiki ke alakaʻi i ka maʻi diarrhea ʻōpū ʻo ia ka Hui F (ʻAno 40 a me 41) [1-8]. Loaʻa i nā ʻano like ʻole nā ​​​​hōʻailona lapaʻau like ʻole, akā ʻo ka mea nui nā maʻi ʻōpū hanu. ʻO nā maʻi hanu i hoʻokumu ʻia e nā maʻi ʻōpū hanu o ke kino kanaka no 5% ~ 15% o nā maʻi hanu honua, a me 5% -7% o nā maʻi hanu kamaliʻi honua [9]. He laha ka Adenovirus ma nā wahi like ʻole a hiki ke loaʻa i ka maʻi i ka makahiki holoʻokoʻa, ʻoi aku hoʻi ma nā wahi i piha i ka poʻe, kahi i maʻalahi i nā maʻi ahulau kūloko, ʻoiai ma nā kula a me nā kahua hoʻomoana koa.

Kanal

ʻOhana adenovirus ākeawaikawa nucleic
ROX

Mana Kūloko

Nā Palena ʻenehana

Ka Waihona

≤-18℃

Ola papa 12 mahina
ʻAno Laʻana ʻUwi nasopharyngealʻUhi ʻāʻī
Ct ≤38
CV ≤5.0%
LoD 300 Kope/mL
Kūlana kikoʻī a) E hoʻāʻo i nā kuhikuhi maikaʻi ʻole o ka ʻoihana maʻamau e ka pahu hana, a hoʻokō ka hopena hoʻāʻo i nā koi.

b) E hoʻohana i kēia pahu hana e ʻike ai a ʻaʻohe cross-reactivity me nā pathogens hanu ʻē aʻe (e like me ka maʻi Influenza A, ka maʻi Influenza B, ka maʻi Respiratory syncytial, ka maʻi Parainfluenza, Rhinovirus, Human metapneumovirus, etc.) a i ʻole bacteria (Streptococcus pneumoniae, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter baumannii, Staphylococcus aureus, etc.).

Nā Mea Hana Pili Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli

Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500

Nā ʻōnaehana PCR Manawa Maoli QuantStudio®5

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.)

ʻŌnaehana PCR Manawa Maoli LightCycler®480

ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plusnā (FQD-96A, Hangzhouʻenehana Bioer)

MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.)

Nā ʻōnaehana PCR Manawa Maoli BioRad CFX96, nā ʻōnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kahe Hana

(1) Mea hoʻohuihui i manaʻo ʻia:ʻO ka Macro & Micro-Test Sample Release Reagent (HWTS-3005-8). Pono e hana ʻia ka unuhi ʻana e like me nā kuhikuhi. ʻO ka hāpana i unuhi ʻia nā mea maʻi'nā laʻana swab nasopharyngeal a i ʻole ka swab ʻāʻī i hōʻiliʻili ʻia ma kahi. E hoʻohui i nā laʻana i loko o ka reagent hoʻokuʻu laʻana e Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., vortex e hui maikaʻi, e kau ma ka mahana o ka lumi no 5 mau minuke, e lawe i waho a laila e hoʻohuli a hui maikaʻi e loaʻa ai ka DNA o kēlā me kēia laʻana.

(2) Mea hoʻohuihui i manaʻo ʻia:Hoʻāʻo Macro & Micro Hoʻolaha maʻi Pahu DNA/RNA(HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) a me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).pono e hana ʻia ka hana e like me nā kuhikuhi. ʻO ka nui o ka laʻana i unuhi ʻia he 200µL, a me kaka nui o ka elution i ʻōlelo ʻiais80μL.

(3) Mea hoʻohui i manaʻo ʻia: Nucleic Acid Extraction a i ʻole Purification Reagent (YDP)315) na Tiangen Biotech (Beijing) Co.,Ltd., kapono e hana ʻia ka hana e like me nā kuhikuhi. ʻO ka nui o ka laʻana i unuhi ʻia he 200µL, a me kaka nui o ka elution i ʻōlelo ʻiais80μL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou