ʻO ka maʻi Herpes Simplex ʻAno 1/2, (HSV1/2) Nucleic Acid

Wehewehe Pōkole:

Hoʻohana ʻia kēia pahu hana no ka ʻike qualitative in vitro o Herpes Simplex Virus Type 1 (HSV1) a me Herpes Simplex Virus Type 2 (HSV2) e kōkua i ka ʻike a me ka mālama ʻana i nā poʻe maʻi me nā maʻi HSV i manaʻo ʻia.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

HWTS-UR018A-Herpes simplex virus type 1/2, (HSV1/2) nucleic acid detection kit (Fluorescence PCR)

ʻAlapia

ʻO nā maʻi i laha ma ke ʻano moekolohe (STD) kekahi o nā hoʻoweliweli nui i ka palekana olakino lehulehu o ka honua. Hiki i kēlā mau maʻi ke alakaʻi i ka hānau ʻole ʻana, ka hānau mua ʻana o ka ʻōpū, ka puʻupuʻu a me nā pilikia koʻikoʻi like ʻole. Nui nā ʻano pathogens STD, me nā bacteria, nā virus, chlamydia, mycoplasma a me nā spirochetes, ʻo ia hoʻi ʻo Neisseria gonorrhoeae, Mycoplasma genitalium, Chlamydia trachomatis, HSV1, HSV2, Mycoplasma hominis, a me Ureaplasma urealyticum he mea maʻamau.

He maʻi maʻamau ka herpes genital i laha ma ke ʻano moekolohe i hoʻokumu ʻia e ka HSV2, he mea laha loa ia. I nā makahiki i hala iho nei, ua piʻi nui ka nui o ka herpes genital, a ma muli o ka piʻi ʻana o nā hana moekolohe weliweli, ua piʻi ka nui o ka ʻike ʻana no ka HSV1 i loko o ka herpes genital a ua hōʻike ʻia he 20%-30%. ʻO ka maʻi mua me ka maʻi herpes genital he mea leo ʻole ia me ka ʻole o nā hōʻailona lapaʻau maopopo koe wale nō ka herpes kūloko i loko o ka mucosa a i ʻole ka ʻili o kekahi mau maʻi. ʻOiai ua hōʻike ʻia ka herpes genital e ka hoʻokahe ʻana o ka viral no ke ola holoʻokoʻa a me ka maʻalahi o ka hoʻi hou ʻana, he mea nui e nānā i nā pathogens i ka hikiwawe loa a ālai i kona laha ʻana.

Kanal

ʻOhana HSV1
CY5 HSV2
VIC(HEX) Mana Kūloko

Nā Palena ʻenehana

Ka Waihona Wai: ≤-18 ℃ I ka pōʻeleʻele
Ola papa 12 mahina
ʻAno Laʻana nā mea huna o ka urethral, ​​nā mea huna o ka cervical
Ct ≤38
CV ≤5.0%
LoD 50 Kope/pane
Kūlana kikoʻī ʻAʻohe hoʻololi keʻa me nā mea maʻi STD ʻē aʻe e like me Treponema pallidum, Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma hominis, Mycoplasma genitalium, a me Ureaplasma urealyticum.
Nā Mea Hana Pili Hiki iā ia ke hoʻokūkū i nā mea hana PCR fluorescent nui ma ka mākeke.

ʻŌnaehana PCR Manawa Maoli Biosystems 7500 i hoʻopili ʻia

Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500

QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P

LightCycler®ʻŌnaehana PCR Manawa Maoli 480

ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus

MA-6000 Mea Hoʻopololei Wela Manawa Maoli

ʻŌnaehana PCR Manawa Maoli BioRad CFX96

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kahe Hana

ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8). Pono e hana pono ʻia ka hoʻoheheʻe ʻana e like me nā kuhikuhi.

Mea hoʻohuihui i ʻōlelo ʻia: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e hana pono ʻia ka hoʻohuihui e like me nā kuhikuhi. Pono ka nui o ka elution i ʻōlelo ʻia he 80 μL.

ʻO ka mea hoʻohuihui i ʻōlelo ʻia: Nucleic Acid Extraction a i ʻole Purification Reagent (YDP315) na Tiangen Biotech (Beijing) Co., Ltd. Pono e hana pono ʻia ka unuhi ʻana e like me nā kuhikuhi. Pono ka nui o ka elution i ʻōlelo ʻia he 80 μL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou