Pahu ʻike waikawa nukleika Ureaplasma Urealyticum (Fluorescence PCR)

Wehewehe Pōkole:

He kūpono kēia pahu hana no ka ʻike ʻana i ka Ureaplasma urealyticum (UU) i loko o nā ʻāpana mimi kāne a me nā ʻāpana hoʻohemo o nā ʻāpana genital wahine ma vitro.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa Huahana

Pahu ʻike waikawa nukleika Ureaplasma Urealyticum (Fluorescence PCR)

ʻAlapia

ʻO Ureaplasma urealyticum (UU) ka microorganism prokaryotic liʻiliʻi loa e hiki ke ola kūʻokoʻa ma waena o nā bacteria a me nā virus, a he microorganism pathogenic hoʻi i maʻalahi i nā maʻi genital a me nā maʻi urinary tract. No ke kāne, hiki iā ia ke hana i ka prostatitis, urethritis, pyelonephritis, a me nā mea ʻē aʻe. No ka wahine, hiki iā ia ke hana i nā hopena mumū i loko o ke ala hānau e like me ka vaginitis, cervicitis, a me ka maʻi mumū pelvic. ʻO ia kekahi o nā pathogens e hoʻoulu ai i ka infertility a me ka abortion. Ua māhele ʻia ʻo Ureaplasma urealyticum i 14 mau serotypes, i māhele ʻia i ʻelua mau pūʻulu e like me nā ʻano biological molecular: hui biological Ⅰ (Up) a me ka hui biological Ⅱ (Uu). Loaʻa i ka Biogroup I 4 mau serotypes me nā genomes liʻiliʻi (1, 3, 6, a me 14); Loaʻa i ka biogroup II nā serotypes 10 i koe me nā genomes nui aʻe.

Kanal

ʻOhana UU waikawa nucleic
VIC(HEX) Mana Kūloko

Nā Palena ʻenehana

Ka Waihona Wai≤-18 ℃ I ka pōʻeleʻele
Ola papa 12 mahina
ʻAno Laʻana mimi kāne, swab urethral kāne, swab cervical wahine
Ct ≤38
CV ≤5.0%
LoD 50 Kope/pane
Kūlana kikoʻī ʻAʻohe cross-reactivity me nā pathogens maʻi STD ʻē aʻe ma waho o ka laulā ʻike o ka kit, e like me Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, herpes simplex virus type 1, a me ka herpes simplex virus type
Nā Mea Hana Pili Hiki iā ia ke hoʻokūkū i nā mea hana PCR fluorescent nui ma ka mākeke.Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa MaoliNā ʻōnaehana PCR Manawa Maoli QuantStudio® 5

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P

ʻŌnaehana PCR Manawa Maoli LightCycler®480

ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus

MA-6000 Mea Hoʻopololei Wela Manawa Maoli

ʻŌnaehana PCR Manawa Maoli BioRad CFX96

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96

Kaʻina hana

Pahu ʻike waikawa nukleika Ureaplasma Urealyticum (Fluorescence PCR)

Pono nā reagents akā ʻaʻole i hāʻawi ʻia

ʻO ka Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Saline maʻamau, hopena mālama mimi.

Pono nā mea hoʻopau akā ʻaʻole i hāʻawi ʻia

1.5mL o ka paipu centrifuge DNase/RNase-free, DNase/RNase-free Tips, ethanol anhydrous, pipette, centrifuge pākaukau, mīkini kāwili noho


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou