Pahu ʻIke STI Multiplex 7

Wehewehe Pōkole:

Kōmike Huahana

HWTS-UR012

Hoʻohana i manaʻo ʻia

Ua manaʻo ʻia kēia pahu hana no ka ʻike ʻana i nā pathogens maʻamau o nā maʻi urogenital, me Neisseria gonorrhoeae (NG), Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), Herpes Simplex Virus Type 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), Mycoplasma hominis (Mh), Mycoplasma genitalium (Mg) i loko o nā ʻāpana mimi kāne a me nā ʻāpana wahine.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa Huahana

Pahu ʻIke STI Multiplex

ʻAlapia

ʻO ka maʻi i laha ma ke ʻano moekolohe (STI) kekahi o nā hoʻoweliweli nui i ka palekana olakino lehulehu o ka honua, hiki ke alakaʻi i ka hānau ʻole ʻana, ka hānau mua ʻana, ka tumorigenesis, a me nā pilikia koʻikoʻi like ʻole. Nui nā ʻano pathogens STI, me nā bacteria, nā virus, chlamydia, mycoplasma, a me nā spirochetes. ʻOi aku ka maʻamau o NG, CT, UU, HSV 1, HSV 2, Mh, Mg.

Nā Palena ʻenehana

Ka Waihona ≤ -18℃
Ola papa 12 mahina
ʻAno Laʻana Nā mea huna urethral, ​​nā mea huna cervical
CV <5.0%
LoD Palena o ka ʻIke ʻana (LoD): ʻO ka LoD o ka pahu no ka ʻike ʻana iā CT, NG, UU, HSV1, HSV2 a me Mg he 400Copies/mL; ʻo ka LoD o ka pahu no ka ʻike ʻana iā Mh he 1000Copies/mL.
Kūlana kikoʻī ʻAʻohe hopena kea me nā maʻi STI like.
Nā Mea Hana Pili

ʻO nā ʻōnaehana PCR manawa maoli Biosystems 7500 i hoʻopili ʻia, nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems 7500 i hoʻopili ʻia, nā ʻōnaehana PCR manawa maoli QuantStudio®5, nā ʻōnaehana PCR manawa maoli SLAN® -96P, ka ʻōnaehana PCR manawa maoli LightCycler® 480, ka ʻōnaehana ʻike PCR manawa maoli LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), ʻōnaehana PCR manawa maoli BioRad CFX96, ʻōnaehana PCR manawa maoli BioRad CFX Opus 96 a pēlā aku.

Kanal

Hoʻopaʻa pane Pahuhopu Mea kākau moʻolelo Mea hoʻopau ahi
Palekana Hoʻoponopono STI 1 CT ʻOhana ʻaʻohe
UU VIC(HEX) ʻaʻohe
Mh ROX ʻaʻohe
HSV1 CY5 ʻaʻohe
Palekana Hoʻoponopono STI 2 NG ʻOhana ʻaʻohe
HSV2 VIC(HEX) ʻaʻohe
Mg ROX ʻaʻohe
IC CY5 ʻaʻohe

Kahe Hana

670e945511776ae647729effe7ec6fa

Pono nā reagents akā ʻaʻole i hāʻawi ʻia

ʻO ka Macro & Micro-Test Sample Release Reagent (HWTS-3005-8); Macro & Micro-Test General DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e hana ʻia ka unuhi ʻana e like me ka IFU.

Pono nā mea hoʻopau akā ʻaʻole i hāʻawi ʻia:1.5mL o ka paipu centrifuge manuahi DNase/RNase, nā ʻōkuhi manuahi DNase/RNase, ka entrifuge pākaukau, ka mīkini hoʻohuihui oscillation pākaukau.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou