Mycoplasma Hominis Nucleic Acid
Inoa huahana
HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Detection Kit (Fluorescence PCR)
ʻAlapia
ʻO nā maʻi i laha ma ke ʻano moekolohe (STD) kekahi o nā hoʻoweliweli koʻikoʻi i ka palekana olakino lehulehu o ka honua, hiki ke alakaʻi i ka hānau ʻole ʻana, ka hānau mua ʻana o ka pēpē, ka tumorigenesis a me nā pilikia koʻikoʻi like ʻole. Aia ka Mycoplasma hominis i loko o ke ala genitourinary a hiki ke hana i nā pane mumū i loko o ke ala genitourinary. Hiki i ka maʻi MH o ke ala genitourinary ke hana i nā maʻi e like me ka urethritis non-gonococcal, epididymitis, a pēlā aku, a i waena o nā wahine, hiki ke hana i ka mumū o ka ʻōnaehana hānau e pālahalaha ana ma ke kikowaena o ka cervix. I ka manawa like, ʻo ka pilikia maʻamau o ka maʻi MH ʻo ia ka salpingitis, a he hapa liʻiliʻi o nā maʻi e loaʻa paha ka endometritis a me ka maʻi mumū pelvic.
Kanal
| ʻOhana | Pahuhopu MH |
| VIC(HEX) | Mana Kūloko |
Nā Palena ʻenehana
| Ka Waihona | Wai: ≤-18 ℃ I ka pōʻeleʻele |
| Ola papa | 12 mahina |
| ʻAno Laʻana | nā mea huna o ka urethral, nā mea huna o ka cervical |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | 1000 Kope/mL |
| Kūlana kikoʻī | ʻAʻohe cross-reactivity me nā pathogens maʻi STD ʻē aʻe, aia ma waho o ka pae ʻike, a ʻaʻohe cross-reactivity me ka chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus type 1, herpes simplex virus type 2, etc. |
| Nā Mea Hana Pili | Hiki iā ia ke hoʻokūkū i nā mea hana PCR fluorescent nui ma ka mākeke. Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli QuantStudio®5 Nā ʻōnaehana PCR Manawa Maoli SLAN-96P ʻŌnaehana PCR Manawa Maoli LightCycler®480 ʻŌnaehana ʻIke PCR Manawa Maoli LineGene 9600 Plus MA-6000 Mea Hoʻopololei Wela Manawa Maoli ʻŌnaehana PCR Manawa Maoli BioRad CFX96 ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96 |
Kahe Hana
Koho 1.
ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8). Pono e hana ʻia ka hoʻoheheʻe ʻana e like me nā kuhikuhi.
Koho 2.
Mea hoʻohuihui i ʻōlelo ʻia: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e hana pono ʻia ka hoʻohuihui e like me nā kuhikuhi. Pono ka nui o ka elution i ʻōlelo ʻia he 80 μL.
Koho 3.
ʻO ka mea hoʻoheheʻe i ʻōlelo ʻia: Nucleic Acid Extraction or Purification Reagent (YDP302) na Tiangen Biotech (Beijing) Co., Ltd.. Pono e hana ʻia ka hoʻoheheʻe ʻana e like me nā kuhikuhi a ʻo ka nui o ka elution i ʻōlelo ʻia he 80µL.













