Mycoplasma Hominis Nucleic Acid
inoa huahana
HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
ʻO nā maʻi i hoʻouna ʻia i ke kāne (STDs) kekahi o nā mea hoʻoweliweli koʻikoʻi i ka palekana olakino o ka honua, hiki ke alakaʻi i ka infertility, hānau hānau mua, tumorigenesis a me nā pilikia koʻikoʻi. Loaʻa ka Mycoplasma hominis i loko o ka ʻāpana genitourinary a hiki ke hana i nā pane ʻeha i ka ʻāpana genitourinary. ʻO ka maʻi MH o ka ʻāpana genitourinary hiki ke hoʻoulu i nā maʻi e like me ka non-gonococcal urethritis, epididymitis, etc., a ma waena o nā wahine, hiki ke hoʻoulu i ka mumū o ka ʻōnaehana hānau e laha ana ma ka ʻōpū. I ka manawa like, ʻo ka hoʻopiʻi maʻamau o ka maʻi MH he salpingitis, a hiki i kahi helu liʻiliʻi o nā maʻi ke loaʻa i ka endometritis a me ka maʻi pelvic inflammatory.
Kanal
FAM | MH pahu hopu |
VIC(HEX) | Hoomalu Kuloko |
Nā ʻāpana ʻenehana
Waihona | Ka wai: ≤-18 ℃ I ka pōʻeleʻele |
Kau-ola | 12 mahina |
ʻAno Hoʻohālike | urethral secretions, huna huna |
Ct | ≤38 |
CV | <5.0% |
LoD | 1000 kope/mL |
kikoo | ʻAʻohe hoʻololi keʻa me nā pathogens maʻi STD ʻē aʻe, aia ma waho o ka pae ʻike, a ʻaʻohe hana keʻa me chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus type 1, herpes simplex virus type 2, etc. |
Nā mea hana pili | Hiki iā ia ke hoʻohālikelike i nā mea hana PCR fluorescent mainstream ma ka mākeke. Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Pūnaehana PCR Manawa maoli SLAN-96P Pūnaehana PCR Manawa maoli LightCycler®480 Pūnaehana PCR manawa maoli LineGene 9600 Plus Pūnaehana ʻike PCR manawa maoli MA-6000 ʻOiaʻiʻo ka nui o ka wela wela BioRad CFX96 Pūnaehana PCR Manawa maoli BioRad CFX Opus 96 Pūnaehana PCR Manawa maoli |
Holo Hana
Koho 1.
Manaʻo ʻia ka mea hoʻoheheʻe: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8). Pono e hana ʻia ka unuhi ʻana e like me nā kuhikuhi.
Koho 2.
Manaʻo ʻia ka hoʻoneʻe ʻana: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (000HWC Acid Extractor). HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e mālama pono ʻia ka unuhi ʻana e like me nā kuhikuhi. ʻO ka nui o ka elution i manaʻo ʻia he 80 μL.
Koho 3.
Manaʻo ʻia ka unuhi ʻana: Nucleic Acid Extraction a Purification Reagent (YDP302) na Tiangen Biotech (Beijing) Co., Ltd.. Pono e hoʻokō ʻia ka unuhi e like me nā kuhikuhi a ʻo ka nui o ka elution i manaʻo ʻia he 80µL.