Treponema Pallidum Nucleic Acid

Wehewehe Pōkole:

He kūpono kēia pahu hana no ka ʻike ʻana i ka Treponema Pallidum (TP) i loko o ka swab urethral kāne, ka swab cervical wahine, a me nā laʻana swab vaginal wahine, a hāʻawi i ke kōkua i ka ʻike ʻana a me ka mālama ʻana i nā maʻi me ka maʻi Treponema pallidum.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

Pahu ʻike waikawa nukleika HWTS-UR047-Treponema Pallidum (Fluorescence PCR)

ʻAlapia

ʻO ka Syphilis kahi maʻi maʻamau i laha ma ke ʻano moekolohe i ka hana lapaʻau, ʻo ia hoʻi kahi maʻi maʻi mau loa i laha ma ke ʻano moekolohe i hoʻokumu ʻia e ka maʻi Treponema Pallidum (TP). Hoʻolaha nui ʻia ka Syphilis ma o ka laha moekolohe, ka laha ʻana mai ka makuahine a i ke keiki a me ka laha koko. ʻO nā maʻi Syphilis wale nō ke kumu o ka maʻi, a hiki ke loaʻa ʻo Treponema pallidum i loko o kā lākou semen, ka waiū umauma, ka lawai a me ke koko. Hiki ke hoʻokaʻawale ʻia ka Syphilis i ʻekolu mau pae e like me ke kaʻina o ka maʻi. Hiki i ka syphilis o ke kahua mua ke hōʻike ʻia ma ke ʻano he chancre paʻakikī a me nā lymph node inguinal pehu, i kēia manawa ka mea laha loa. Hiki i ka syphilis o ke kahua lua ke hōʻike ʻia ma ke ʻano he ʻulaʻula syphilitic, emi ka chancre paʻakikī, a ikaika hoʻi ka maʻi. Hiki i ka syphilis o ke kahua tertiary ke hōʻike ʻia ma ke ʻano he syphilis iwi, neurosyphilis, a pēlā aku.

Nā Palena ʻenehana

Ka Waihona

-18℃

Ola papa 12 mahina
ʻAno Laʻana ʻUlu urethral kāne, ʻulu cervical wahine, ʻulu vaginal wahine
Ct ≤38
CV ≤10.0%
LoD 400 Kope/μL
Nā Mea Hana Pili Pili i ka mea hana ʻike ʻano I:

Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli,

QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli,

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.),

Nā ʻōnaehana ʻike PCR manawa maoli ʻo LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer),

MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.),

ʻŌnaehana PCR Manawa Maoli BioRad CFX96,

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96.

Pili i ka mea hana ʻike ʻano II:

ʻEudemonaTMʻO AIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Kahe Hana

ʻO ka Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), a me ka Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (hiki ke hoʻohana ʻia me EudemonTM ʻO AIO800 (HWTS-EQ007)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

ʻO ka nui o ka hāpana i unuhi ʻia he 200μL a ʻo ka nui o ka elution i ʻōlelo ʻia he 150μL.