Pahu ʻike waikawa nucleic Treponema Pallidum

Wehewehe Pōkole:

He kūpono kēia pahu hana no ka ʻike ʻana i ka Ureaplasma Parvum (UP) i loko o nā ʻāpana mimi kāne a me nā ʻāpana hānau wahine, a hāʻawi i ke kōkua i ka ʻike a me ka mālama ʻana i nā maʻi me ka maʻi Ureaplasma parvum.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

Pahu ʻike waikawa nucleic Treponema Pallidum

ʻAlapia

Ua māhele ʻia nā ʻano Ureaplasma e pili ana i ka pathogenesis kanaka i 2 mau biogroups a me 14 mau serotypes. ʻO ka Biogroup Ⅰ ʻo Ureaplasma urealyticum, nona nā serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, a me 13. ʻO ka Biogroup Ⅱ ʻo Ureaplasma parvum, nona nā serotypes: 1, 3, 6, 14. He parasite maʻamau a commensal paha ʻo Ureaplasma ma ke ala hānau haʻahaʻa o ka wahine a ʻo ia kekahi o nā pathogens koʻikoʻi e hoʻoulu ai i nā maʻi lele i loko o ka ʻōnaehana genitourinary. Ma waho aʻe o ka hoʻoulu ʻana i nā maʻi genitourinary tract, ʻo nā wahine me ka maʻi Ureaplasma e hoʻoili nui i ka pathogen i kā lākou hoa moe. ʻO ka maʻi Ureaplasma kekahi o nā kumu koʻikoʻi o ka infertility. Inā loaʻa i nā wahine hāpai ka Ureaplasma, hiki iā ia ke alakaʻi i ka haki mua ʻana o nā membranes, ka hānau mua ʻana, ka neonatal respiratory distress syndrome, ka maʻi postpartum a me nā hopena ʻino ʻē aʻe o ka hāpai ʻana, e pono ai ka nānā nui.

Nā Palena ʻenehana

Ka Waihona

-18℃

Ola papa 12 mahina
ʻAno Laʻana ʻōnaehana mimi kāne, ʻōnaehana hānau wahine
Ct ≤38
CV <5.0%
LoD 400 Kope/mL
Nā Mea Hana Pili Pili i ka mea hana ʻike ʻano I:

Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli,

QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli,

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.),

Nā ʻōnaehana ʻike PCR manawa maoli ʻo LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer),

MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.),

ʻŌnaehana PCR Manawa Maoli BioRad CFX96,

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96.

Pili i ka mea hana ʻike ʻano II:

ʻEudemonaTMʻO AIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Kaʻina hana

Kiʻi o ke kaʻina hana

Pono ka reagent akā ʻaʻole i hāʻawi ʻia

ʻO ka saline maʻamau, Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Pono nā mea hoʻopau akā ʻaʻole i hāʻawi ʻia

Nā wēlau manuahi ʻo RNase/DNase, nā paipu centrifuge manuahi ʻo RNase/DNase 1.5 mL, centrifuge pākaukau, vortex Mixer


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou