Ka maʻi kuni koko o Xinjiang
Inoa huahana
Pahu ʻike waikawa nukleika no ka maʻi fiva hemorrhagic Xinjiang HWTS-FE007B/C (Fluorescence PCR)
ʻAlapia
Ua hoʻokaʻawale mua ʻia ka maʻi kuni hemorrhagic Xinjiang mai ke koko o nā maʻi me ke kuni hemorrhagic ma ke kahawai ʻo Tarim, Xinjiang, Kina a me nā ʻūpā paʻakikī i hopu ʻia ma kahi kūloko, a ua loaʻa iā ia kona inoa. ʻO nā hōʻike lapaʻau e pili ana i ke kuni, ka ʻeha poʻo, ke kahe koko, ka haʻalulu hypotensive, a me nā mea ʻē aʻe. ʻO nā loli pathological kumu o kēia maʻi he dilatation capillary systemic, congestion, hoʻonui permeability a me ka fragility, e hopena ana i nā ʻano like ʻole o ka congestion a me ke kahe koko i loko o ka ʻili a me nā membrane mucous a me nā ʻiʻo o nā ʻano kino like ʻole ma ke kino, me ka degeneration a me ka necrosis o nā ʻano kino paʻa e like me ke akepaʻa, ka adrenal gland, ka pituitary gland, a me nā mea ʻē aʻe, a me ka edema jelly-like ma ka retroperitoneum.
Kanal
| ʻOhana | Ka maʻi kuni koko o Xinjiang |
| ROX | Mana Kūloko |
Nā Palena ʻenehana
| Ka Waihona | ≤-18℃ |
| Ola papa | 9 mahina |
| ʻAno Laʻana | serum hou |
| Tt | ≤38 |
| CV | <5.0% |
| LoD | 1000 Kope/mL |
| Kūlana kikoʻī | ʻAʻohe cross-reactivity me nā hāpana hanu ʻē aʻe e like me Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3, Coxsackie virus, Echo virus, Metapneumovirus A1/A2/B1/B2, Respiratory syncytial virus A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, etc. a me ka DNA genomic kanaka. |
| Nā Mea Hana Pili | Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli, Nā ʻōnaehana PCR manawa maoli wikiwiki Biosystems i hoʻopili ʻia 7500 QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli Nā ʻōnaehana PCR Manawa Maoli SLAN-96P LightCycler®ʻŌnaehana PCR Manawa Maoli 480 Nā ʻōnaehana ʻike PCR manawa maoli LineGene 9600 Plus MA-6000 Mea Hoʻopololei Wela Manawa Maoli ʻŌnaehana PCR Manawa Maoli BioRad CFX96 ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96 |
Kahe Hana
Mea hoʻohuihui i ʻōlelo ʻia: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Pono e hana ʻia ka hoʻohuihui e like me ke kuhikuhi no ka hoʻohana ʻana i kēia mea hoʻohuihui. ʻO ka nui o ka laʻana i hoʻohuihui ʻia he 200µL, a ʻo ka nui o ka elution i ʻōlelo ʻia he 80µL.
ʻO ka mea hoʻohuihui i ʻōlelo ʻia: QIAamp Viral RNA Mini Kit (52904) e QIAGEN a me Nucleic Acid Extraction a i ʻole Purification Reagent (YDP315-R). Pono e hana ʻia ka hoʻohuihui e like me nā kuhikuhi no ka hoʻohana ʻana. ʻO ka nui o ka laʻana i unuhi ʻia he 140µL, a ʻo ka nui o ka elution i ʻōlelo ʻia he 60µL.







