ʻO Zaire Ebola Virus

ʻO ka wehewehe pōkole:

He mea kūpono kēia kit no ka ʻike kūpono o Zaire Ebola virus nucleic acid i ka serum a i ʻole plasma samples o nā maʻi i manaʻo ʻia he maʻi Zaire Ebola (ZEBOV).


Huahana Huahana

Huahana Huahana

Inoa mea kūʻai

HWTS-FE008 Zaire Ebola Virus Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

No Filoviridae ka ma'i Ebola, 'o ia ka ma'i ma'i ma'i ma'i ma'i 'ino-'ole i wae 'ia.ʻO nā maʻi virus he mau filament lōʻihi me ka awelika virion lōʻihi o 1000nm a me ke anawaena o kahi 100nm.ʻO ka genome maʻi Ebola he RNA ʻino-ʻole i hoʻokaʻawale ʻia me ka nui o 18.9kb, e hoʻopili ana i 7 mau protein kūkulu ʻia a me 1 protein non-structural.Hiki ke hoʻokaʻawale ʻia ka maʻi Ebola i nā ʻano like me Zaire, Sudan, Bundibugyo, Tai Forest a me Reston.Ma waena o lākou, ua hōʻike ʻia ke ʻano Zaire a me ke ʻano Sudan i mea e make ai ka poʻe he nui mai ka maʻi.ʻO EHF (Ebola Hemorrhagic Fever) he maʻi maʻi maʻi hemorrhagic i hoʻokumu ʻia e ka maʻi Ebola.Hoʻopili nui ʻia nā kānaka ma ka hoʻopili ʻana me nā wai kino, nā mea huna a me nā excreta o nā mea maʻi a i ʻole nā ​​​​holoholona maʻi, a ʻo nā hōʻike lapaʻau ka nui o ke kuni, ke koko a me nā pōʻino kino he nui.He kiʻekiʻe ka nui o ka make o ka EHF ma 50%-90%.

Kanal

FAM ʻakika nucleic MP
ROX

Hoomalu Kuloko

Nā ʻāpana ʻenehana

Waihona

≤-18 ℃

Kau-ola 9 mahina
ʻAno Hoʻohālike Serum hou, Plasma
Tt ≤38
CV ≤5.0%
LoD 500 kope/μL
kikoo E hoʻohana i nā kits e hoʻāʻo ai i nā kuhikuhi maikaʻi ʻole o ka hui, kūpono nā hopena i nā koi.
Nā mea hana pili Hoʻohana ʻia Biosystems 7500 Pūnaehana PCR manawa maoli

Hoʻohana ʻia ʻo Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Pūnaehana PCR Manawa maoli

SLAN-96P Pūnaehana PCR manawa maoli (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Pūnaehana PCR manawa maoli

LineGene 9600 Plus Pūnaehana ʻike PCR manawa maoli (FQD-96A, ʻenehana Hangzhou Bioer)

MA-6000 Mea Hoʻokele Thermal Cycler manawa maoli (Suzhou Molarray Co., Ltd.)

ʻO BioRad CFX96 Pūnaehana PCR manawa maoli, a me BioRad CFX Opus 96 Pūnaehana PCR manawa maoli.

Holo Hana

Koho 1.

Manaʻo ʻia ka mea hoʻoneʻe hoʻoneʻe: QIAamp Viral RNA Mini Kit (52904), Nucleic Acid Extraction a i ʻole Purification Reagent (YDP315-R) na Tiangen Biotech (Beijing) Co., Ltd.Pono e unuhi ʻia e like me nā ʻōlelo aʻoaʻo, a ʻo ka nui o ka unuhi ʻana o ka hāpana ʻo 140μL a ʻo ka nui elution i ʻōlelo ʻia he 60μL.

Koho 2.

Manaʻo ʻia ka hoʻoulu ʻana: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) a me Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006). pono e unuhi e like me na kuhikuhi.ʻO 200μL ka nui o ka laʻana, a ʻo ka nui elution i ʻōlelo ʻia he 80μL.

Koho 3.

Manaʻo ʻia nā reagents unuhi: Nucleic Acid Extraction Reagent (1000020261) a me High Throughput Automated Sample Preparation System (MGISP-960) e BGI pono e unuhi ʻia e like me nā kuhikuhi.ʻO ka nui o ka unuhi ʻana he 160μL, a ʻo ka nui elution i ʻōlelo ʻia he 60μL.


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou