ʻO ka waikawa nucleic Gardnerella Vaginalis

Wehewehe Pōkole:

He kūpono kēia pahu hana no ka ʻike ʻana i ka Gardnerella vaginalis nucleic acid i loko o nā swab urethral kāne, nā swab cervical wahine, a me nā laʻana swab vaginal wahine.


Nā kikoʻī huahana

Nā Lepili Huahana

Inoa huahana

HWTS-UR042-Gardnerella Vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)

ʻAlapia

ʻO ke kumu maʻamau o ka vaginitis i nā wahine, ʻo ia ka bacterial vaginosis, a ʻo ka bacteria pathogenic koʻikoʻi o ka bacterial vaginosis ʻo Gardnerella vaginalis. ʻO Gardnerella vaginalis (GV) kahi pathogen opportunistic ʻaʻole ia e hoʻoulu i ka maʻi ke loaʻa i nā liʻiliʻi. Eia nō naʻe, i ka wā e hoʻemi ʻia ai a hoʻopau ʻia paha nā bacteria vaginal dominant Lactobacilli, e hana ana i kahi kaulike ʻole i loko o ke kaiapuni vaginal, hoʻonui nui ʻo Gardnerella vaginalis i nā helu he nui, e alakaʻi ana i ka bacterial vaginosis. I ka manawa like, ʻoi aku ka nui o nā pathogens ʻē aʻe (e like me Candida, Neisseria gonorrhoeae, Chlamydia trachomatis, etc.) e hoʻouka i ke kino o ke kanaka, e hana ana i ka vaginitis hui ʻia a me ka cervicitis. Inā ʻaʻole i ʻike ʻia a mālama ʻia ka vaginitis a me ka cervicitis i ka manawa kūpono a me ka maikaʻi, aia paha nā maʻi piʻi e nā pathogens ma ka mucosa o ke ala hānau, e alakaʻi maʻalahi ana i nā maʻi o ke ala hānau kiʻekiʻe e like me endometritis, salpingitis, tubo-ovarian abscess (TOA), a me ka pelvic peritonitis, hiki ke alakaʻi i nā pilikia koʻikoʻi e like me ka infertility, ka hāpai ʻana o ka ectopic a me nā hopena hāpai maikaʻi ʻole.

Nā Palena ʻenehana

Ka Waihona

-18℃

Ola papa 12 mahina
ʻAno Laʻana nā ʻūpā urethral kāne, nā ʻūpā cervical wahine, nā ʻūpā vaginal wahine
Ct ≤38
CV <5.0%
LoD 400 Kope/mL
Nā Mea Hana Pili Pili i ka mea hana ʻike ʻano I:Nā ʻōnaehana Biosystems i hoʻopili ʻia 7500 Nā ʻōnaehana PCR Manawa Maoli,

QuantStudio®5 mau ʻōnaehana PCR Manawa Maoli,

Nā ʻōnaehana PCR Manawa Maoli SLAN-96P (Hongshi Medical Technology Co., Ltd.),

Nā ʻōnaehana ʻike PCR manawa maoli ʻo LineGene 9600 Plus (FQD-96A, ʻenehana Hangzhou Bioer),

MA-6000 Mea Hoʻopololei Wela Manawa Maoli (Suzhou Molarray Co., Ltd.),

ʻŌnaehana PCR Manawa Maoli BioRad CFX96,

ʻŌnaehana PCR Manawa Maoli BioRad CFX Opus 96.

Pili i ka mea hana ʻike ʻano II:

ʻEudemonaTMʻO AIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Kahe Hana

ʻO ka Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (hiki ke hoʻohana ʻia me ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), a me ka Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (hiki ke hoʻohana ʻia me EudemonTM ʻO AIO800 (HWTS-EQ007)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

ʻO ka nui o ka hāpana i unuhi ʻia he 200μL a ʻo ka nui o ka elution i ʻōlelo ʻia he 150μL.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou